Plug-in lightning current arrester for higher nominal voltages, according to Type 1/Class I, for 3-phase power supply networks in TN and IT versions (L1, L2, L3, PE).

Price:

Save money: Best price starts from {0} pieces!
current article

Your advantages

  • Surge protection family for universal use with optimum energy coordination from the lightning current arrester to the device protection
  • Easy to maintain due to consistently pluggable protection modules
  • Excellent level of information provided by mechanical/visual status indicator and remote indication contact
  • Optimum protective effect in the event of high-energy lightning currents, thanks to spark gap technology with low residual voltage characteristic
  • Maximum performance in a minimum amount of space: compact design with high discharge capacity at high nominal voltage
logo_rohs.gif Logo Logo Logo

Key Commercial Data

Orderkey 2905988
Packing unit 1 pc
Sales key CL1172 -
Catalog page Page 35 (C_4_2019)
GTIN 4055626013275
Weight per Piece (excluding packing) 1,084.000 g
Custom tariff number 85363030
Country of origin DE (Germany)

Drawings



Dimensional drawing 

Dimensional drawing

Product drawing 

Product drawing



Circuit diagram 

Circuit diagram

Back to top

Dimensions

Height 95.2 mm
Width 106.8 mm
Depth 74.5 mm
Horizontal pitch 6 Div.
Back to top

Ambient conditions

Degree of protection IP20 (only when all terminal points are used)
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation) 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Back to top

General

IEC test classification I / II
T1 / T2
EN type T1 / T2
IEC power supply system TN-C
IT
Mode of protection L-PE
L-PEN
Mounting type DIN rail: 35 mm
Color light grey RAL 7035
traffic grey A RAL 7042
Housing material PA 6.6-FR 20 % GF
PBT-FR
Degree of pollution 2
Flammability rating according to UL 94 V-0
Type DIN rail module, two-section, divisible
Number of positions 3
Surge protection fault message Optical, remote indicator contact
Back to top

Protective circuit

Nominal voltage UN 400/690 V AC (TN-C)
400 V AC (IT)
Nominal frequency fN 50 Hz (60 Hz)
Maximum continuous voltage UC 440 V AC
Rated load current IL 125 A (< 55 °C)
Residual current IPE < 5 µA
Nominal discharge current In (8/20) µs 35 kA
Maximum discharge current Imax (8/20) µs 50 kA
Impulse discharge current (10/350) µs, charge 17.5 As
Impulse discharge current (10/350) µs, specific energy 310 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp 35 kA
Follow current interrupt rating Ifi 50 kA
Short-circuit current rating ISCCR 50 kA
Voltage protection level Up ≤ 2.5 kV
Residual voltage Ures ≤ 2.5 kV (at In)
≤ 2.7 kV (at Imax)
≤ 2 kV (at 17.5 kA)
≤ 1.7 kV (at 7 kA)
≤ 1.5 kV (at 3.5 kA)
TOV behavior at UT 580 V AC (5 s / withstand mode)
800 V AC (120 min / withstand mode)
1640 V AC (200 ms / safe failure mode)
Response time tA ≤ 100 ns
Max. backup fuse with V-type through wiring 125 A (gG)
Max. backup fuse with branch wiring 400 A (gG)
Back to top

Indicator/remote signaling

Switching function Changeover contact
Operating voltage 12 V AC ... 250 V AC
125 V DC (200 mA DC)
Operating current 10 mA AC ... 1 A AC
1 A DC (30 V DC)
Connection method Plug-in/screw connection via COMBICON
Screw thread M2
Tightening torque 0.25 Nm
Stripping length 7 mm
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Conductor cross section solid 0.14 mm² ... 1.5 mm²
Conductor cross section AWG 28 ... 16
Back to top

Connection data

Connection method Screw connection
Screw thread M5
Tightening torque 4.5 Nm
Stripping length 18 mm
Conductor cross section flexible 2.5 mm² ... 35 mm²
Conductor cross section solid 2.5 mm² ... 35 mm²
Conductor cross section AWG 13 ... 2
Connection method Fork-type cable lug
Conductor cross section flexible 1.5 mm² ... 16 mm²
Back to top

UL specifications

SPD Type 2CA
Maximum continuous operating voltage MCOV (L-L) 880 V AC
Maximum continuous operating voltage MCOV (L-G) 440 V AC
Nom. voltage 400 V AC
400/690 V AC
Rated load current IL 50 A
Mode of protection L-L
L-G
Power distribution system Delta
Wye
Nominal frequency 50/60 Hz
Voltage protection rating VPR (L-L) 3000 V
Voltage protection rating VPR (L-G) 1800 V
Nominal discharge current In 20 kA
Short-circuit current rating (SCCR) 25 kA
Back to top

UL indicator/remote signaling

Operating voltage 125 V AC
Operating current 1 A AC
Tightening torque 4 lbf-in.
Conductor cross section AWG 30 ... 14
Back to top

UL connection data

Conductor cross section AWG 3 ... 2
Tightening torque 40 lbf-in.
Back to top

Standards and Regulations

Standards/regulations IEC 61643-11 2011
EN 61643-11 2012
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
N,N-dimethylacetamide 127-19-5
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

ECLASS

ECLASS 10.0.1 27130802
ECLASS 11.0 27130802
ECLASS 4.0 27130800
ECLASS 4.1 27130800
ECLASS 5.0 27130800
ECLASS 5.1 27130800
ECLASS 6.0 27130800
ECLASS 7.0 27130802
ECLASS 9.0 27130802
Back to top

ETIM

ETIM 4.0 EC000381
ETIM 6.0 EC000381
ETIM 7.0 EC000381
Back to top

UNSPSC

UNSPSC 13.2 39121620
UNSPSC 18.0 39121620
UNSPSC 19.0 39121620
UNSPSC 20.0 39121620
UNSPSC 21.0 39121620
Back to top

PHOENIX CONTACT Ltd

Halesfield 13
Telford
Shropshire
TF7 4PG
01952 681700