Application-optimised and prewired combined lightning current and surge arrester for single-phase TT and TN systems with a nominal voltage of 230 V (1+1 configuration); with floating remote signalling contact
Application-optimised two-pole combined arrester for 230/400 V TT systems With remote signalling contact for the monitoring device (floating changeover contact) SPD type 1 + type 2 in accordance with EN 61643-11 For use in compact and simply equipped electrical installations with reduced technical requirements Spark gap technology with follow current limitation Operating state/fault indication by indicator flag in the inspection window Leakage-current-free, non-exhausting design Max. continuous operating voltage: 255 V a.c. Voltage protection level: <= 1.5 kV Lightning impulse current (10/350): 25 kA Energy coordinated in accordance with IEC 62305-4 (VDE 0185-305-4) with type 2 and 3 arresters of the Red/Line family, as well as directly coordinated with terminal equipment DIN rail mounted device in accordance with DIN 43880, 2 modules
delivery and installation.
Brand: DEHN + SÖHNE
Type: DSH TT 2P 255 FM
Part No.: 941 115
or equivalent.
Type |
DSH TT 2P 255 FM |
Part No. |
941 115 + |
SPD according to EN 61643-11 / IEC 61643-11 |
type 1 + type 2 / class I + class II |
Energy coordination with terminal equipment (≤ 5 m) |
type 1 + type 2 + type 3 |
Nominal voltage (a.c.) (UN) |
230 V (50 / 60 Hz) |
Max. continuous operating voltage (a.c.) (UC) |
255 V (50 / 60 Hz) |
Lightning impulse current (10/350 µs) [L+N-PE] (Itotal) |
25 kA |
Specific energy [L+N-PE] (W/R) |
156.25 kJ/ohms |
Lightning impulse current (10/350 µs) [L-N]/[N-PE] (Iimp) |
12.5 / 25 kA |
Specific energy [L-N]/[N-PE] (W/R) |
39.06 / 156.25 kJ/ohms |
Nominal discharge current (8/20 µs) [L-N]/[N-PE] (In) |
12.5 / 25 kA |
Voltage protection level [L-N]/[N-PE] (UP) |
≤ 1.5 / ≤ 1.5 kV |
Follow current extinguishing capability [L-N]/[N-PE] (Ifi) |
25 kArms / 100 Arms |
Follow current limitation / Selectivity |
no tripping of a 32 A gG fuse up to 25 kArms (prosp.) |
Response time (tA) |
≤ 100 ns |
Max. mains-side overcurrent protection |
160 A gG |
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic |
440 V / 120 min. – withstand |
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic |
1200 V / 200 ms – withstand |
Operating temperature range (TU) |
-40 °C ... +80 °C |
Operating state / fault indication |
green / red |
Number of ports |
1 |
Cross-sectional area (L, N, PE, 9) (min.) |
1.5 mm2 solid / flexible |
Cross-sectional area (L, N, PE, 9) (max.) |
35 mm2 stranded / 25 mm2 flexible |
For mounting on |
35 mm DIN rails acc. to EN 60715 |
Enclosure material |
thermoplastic, red, UL 94 V-0 |
Place of installation |
indoor installation |
Degree of protection |
IP 20 |
Capacity |
2 module(s), DIN 43880 |
Approvals |
KEMA, VDE |
Type of remote signalling contact |
changeover contact |
Switching capacity (a.c.) |
250 V / 0.5 A |
Switching capacity (d.c.) |
250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
Cross-sectional area for remote signalling terminals |
max. 1.5 mm2 solid / flexible |
Extended technical data: |
--------------------------------- |
Voltage protection level [L-PE] (UP) |
2.0 kV |
Weight |
285 g |
GTIN |
4013364289208 |
PU |
1 pc(s) |
Part No. |
941 115 |