Product Description
OBV7 series surge protective device (in short: SPD, alias: surge protector, surge arrester) is suitable for TN-S,TN-C-S,TT,IT etc. power supply system of AC 50/60Hz, ≤380V, and used at the equipotential connection, which protects the electric network not shocked by the thunder and lightning, it’s designed according to GB18802.1,IEC61643-1, it adopts 35mm standard rail, there is a failure release mounted on the module of surge protective device. When the SPD fails in breakdown for over-heat and over-current, the failure release will help electric device separate from the power system and give the indication signal, green means normal, red means abnormal. Kevin wiring mode, remote-signaling output interface. It’s also could be replaced for the module when has operating voltage.
Model and Meaning
Application Scope and Installation Position
OBV7-150,OBV7-120,OBV7-100 series surge protective devices are suitable for B grade lightning-proof, used at the equipotential connection of LPZOA or LPZOB and LPZ1 zone, which protects the electric network not shocked by the thunder. OBV7-80,OBV7-60 series surge protective devices are usually installed in low voltage main distribution box connected to the incoming end of the buildings.
Notice: When you order our goods, please write the model and quantity carefully. For example: OBV7-80/4-385, 8 pieces.
Main Technical Parameters
OBV7-60
OBV7-80
OBV7-100
OBV7-120
Max. Continuous Operating Voltage Uc (V~)
385V
420V
385V
420V
385V
420V
385V
420V
Voltage Protection Level Up (V~) kV
1.8
2.2
2.5
2.5
2.5
2.8
2.5
3.0
Nominal Discharge Current In(8/20µs)kA
30kA
40kA
60
80kA
Maximum Discharge Current Imax(8/20µs)kA
60kA
80kA
100
120kA
Response Time ns
<25
L/N(mm2) The Cross Section of L/N Line
25-35 mm2
The Cross Section of PE Line
25-35 mm2
Fuse or Switch (A)
10
The Line Section of Communication and Alarm
10A��16A
16A��25A
Operating Environment OC
15
Relative Humidity (25OC)
-40OC~+85OC
Installation
95%
Material of Outer Covering
Standard Rail 35mm
Rated Operating Voltage Un (V~)
Fiberglass
Dimension